SIEMENS(西门子)程控器:
西门子LOA24.171B27、LOA44.252A27,LAL1.25,LAL2.25,LAL2.65,LMG22.330A27,LMG21.330B27、LMG22.330B27,LMG25.330,LGB21.330A27,LGB22.330A27,LFL1.322,LFL1.333,LFL1.335,LFL1.635,LFE10, LOK16.250A27程控器 巴拿玛VM42,VM41,SM592.21,SM152.2,GF2,GF3,MF2,CM381,OR3/B,SR3,G22S.03N,G22,S09.N,VE3.2 程控器 利雅路530SE,503SE,RMO503,RMO88.530,552SE,522SE,525SE,508SE,813SE,RMG88.620A2程控器
燃油电磁阀:121C2323、121K2423、122K9321、321H2322、321H2520、7121ZBG1KRT0,121K6220,E131K13,121V5163,E121K23,E121K64,321H7306,121K2423,122K9321,321H2322,121C2323,121G2320,XT-09,ZB15,ZH14等
产品说明: |
LGB21系列燃气燃烧器控制器
品牌:SIEMENS(西门子)
产地:德国 |
产品介绍 |
The LGB... burner controls are used for the startup and *vision of single- or 2-stage gas or gas / oil burners in intermittent operation. Depending on the t*e of burner control used, the flame is *vised either by an ionization probe, a blue-flame detector QRC1... for forced draft gas / oil burners, or a UV detector QRA... (with auxiliary unit AGQ1...A27).
In connection with the respective adapters, the LGB... burner controls replace their predecessor t*es LFI7... and LFM1... (also refer to ?Replacement t*es under Ordering).
-
Automatic forced draft burners for gaseous fuels to EN 676
-
Gas burner controls to EN 298
-
Undervoltage detection
-
Air pressure *vision with functional check of the air pressure monitor during startup and operation
-
Electrical remote reset facility
-
LGB41... for use with atmospheric gas burners |
型号表 |
型号 |
认证 |
tw/s |
t1/s |
TSA/s |
t3n/s |
t3/s |
t4/s |
t9/s |
t10/s |
t11/s |
t12/s |
t20/s |
LGB21.130A27 |
CH,EU,S,SF |
8 |
7 |
3 |
2.4 |
2 |
8 |
- |
5 |
- |
- |
6 |
LGB21.230A27 |
CH,EU,S,SF |
8 |
15 |
3 |
2.4 |
2 |
8 |
- |
5 |
- |
- |
38 |
LGB21.330A27 |
CH,EU,H,S,SF |
8 |
30 |
3 |
2.4 |
2 |
8 |
- |
5 |
- |
- |
23 |
LGB21.350A27 |
CH,EU,H,S,SF |
8 |
30 |
5 |
4 |
2 |
10 |
- |
5 |
- |
- |
2 |
LGB21.550A27 |
AUS,DH,EU |
8 |
50 |
5 |
4 |
2 |
10 |
- |
5 |
- |
- |
2 |
LGB22.130A27 |
CH,EU,N,S |
9 |
7 |
3 |
2.4 |
3 |
8 |
- |
3 |
12 |
12 |
21 |
LGB22.230B27 |
CH,EU,N,S,SF |
9 |
20 |
3 |
2.4 |
3 |
8 |
- |
3 |
16.5 |
16.5 |
2 |
LGB22.330A27 |
AUS,CH,EU,H,N,S,SF |
9 |
30 |
3 |
2.4 |
3 |
8 |
- |
3 |
12 |
11 |
2 |
LGB22.330A270 |
EU |
9 |
30 |
3 |
2.4 |
3 |
8 |
- |
3 |
12 |
11 |
2 |
LGB32.130A27 |
CH,EU |
9 |
7 |
3 |
2.4 |
3 |
8 |
- |
3 |
12 |
12 |
21 |
LGB32.230A27 |
CH,EU |
9 |
20 |
3 |
2.4 |
3 |
8 |
- |
3 |
16.5 |
16.5 |
2 |
LGB32.330A27 |
CH,EU |
9 |
30 |
3 |
2.4 |
3 |
8 |
- |
3 |
12 |
11 |
2 |
LGB32.350A27 |
CH,EU |
9 |
30 |
5 |
4.4 |
1 |
10 |
- |
3 |
12 |
9 |
2 |
LGB41.255A27 |
EU |
18 |
- |
5 |
4 |
2 |
10 |
5 |
- |
- |
- |
10 |
LGB41.258A27 |
CH,EU,H,SF |
18 |
- |
5 |
4 |
2 |
10 |
9 |
- |
- |
- |
10 | |
tw |
等待时间 |
t1 |
预吹扫时间 |
TSA |
点火*时间 |
t3 |
预点火时间 |
t3n |
后点火时间 |
t4 |
电磁阀1到电磁阀2的间隔时间,或电磁阀1到比例控制开始的间隔时间 |
t9 |
第二*时间(*LGB41...) |
t10 |
空气压力信号建立时间 |
t11 |
伺服马达程序打开时间 |
t12 |
伺服马达程序关闭时间 |
t20 |
自锁定后的程序内部循环时间 | | |
技术参数 |
主要参数 |
主电压 |
AC220V -15%...AC240V +10%(LGB2../LGB4...) |
AC230V -15%/+10%(LGB32...) |
AC100V -15%...AC110V +10% |
主频率 |
50...60Hz ±6% |
外部保险丝 |
10A |
功率 |
3VA |
重量 |
230g |
保护等级 |
IP40 |
额定电流 |
|
端子3 |
3A(可在0.5S内到15A) |
端子4,5,7 |
2A |
端子9,10 |
1A |
端子12 |
5A | | | |
环境条件 |
运输环境 |
IEC 721-3-2 |
内部条件 |
cl* 2K2 |
温度范围 |
-50...+60ºC |
机械条件 |
cl* 2M2 |
湿度 |
<95% |
运行环境 |
IEC 721-3-3 |
内部条件 |
cl* 3K5 |
机械条件 |
cl* 3M2 |
温度范围 |
-20...+60ºC |
湿度 |
<95% |
不得进水 | | | |