图文详情
产品属性
相关推荐
武汉欧陆直流调速器维修变频技术研发基地
我厂长期从事欧陆直流调速器维修,欧陆变频器维修,欧陆触摸屏维修,欧陆伺服器维修,欧陆驱动器维修,欧陆伺服驱动器维修。具有整套检测设备,经验丰富,价格实在,周期短,*率高,擅长解决各种疑难杂症,欢迎来电咨询:
欧陆直流调速器维修型号有:派克(parker)欧陆SSD512C、514C、590C、590P/591P、590+直流调速器、欧陆590直流调速器、欧陆590+直流调速器;欧陆ER-ER3200系列、欧陆ER-ER3600系列、欧陆ER-ERPL系列、欧陆ER-ERPLX系列
欧陆产品维修的部分型号:
590P/0015/500/P/0035/500/P/0040/500/P/0070/500/P/0110/500/P/0165/500/P/0180/500/P/0270/500/P/0380/500/P/0500/500/P/0725/500/P/0830/500/P/1580/500/P/2200/500/P/2700/500/0011
591P/0015/500/P/0035/500/P/0040/500/P/0070/500/P/0110/500/P/0165/500/P/0180/500/P/0270/500/P/0380/500/0041591P/0500/500/P/0725/500/P/0830/500/P/1580/500/P/2200/500/P/2700/500/P/0380/600/P/0500/600/P/0725/600/P/0830/600/P/1580/600/P/2200/690/P/2700/690/P/1200/500/P/1200/690/0011
512C/040/00 512C/080/00 512C/160/00 512C/320/00 514C/040/00 514C/080/00 514C/160/00 514C/320/00
690PB/0007/230/1/F/PB/0015/230/1/F/PB/0022/230/1/F/PB/0007/230/1/0/PB/0015/230/1/0/0011、690PB/0022/230/1/0/PB/0007/230/3/F/PB/0015/230/3/F/0011、690PB/0022/230/3/F/PB/0040/230/3/F/PB/0007/230/3/0/0011、690PB/0015/230/3/0/PB/0022/230/3/0/PB/0040/230/3/0/0011、690PD/0110/230/PD/0150/230/PD/0180/230/PE/0220/230/PF/0300/230/PF/0370/230/PF/0450/230/PC/0055/230/0011..B0 690PC/0075/230/0011..B0 690PD/0110/230/0011..B0 690PD/0150/230/0011..B0 690PD/0180/230/0011..B0 690PE/0220/230/0011..B0 690PF/0300/230/0011..B0 690PF/0370/230/0011..B0 690PF/0450/230/0011..B0 690PB/0007/400/3/F/PB/0015/400/3/F/PB/0022/400/3/F/PB/0040/400/3/F/PB/0055/400/3/F/PB/0007/400/3/0/PB/0015/400/3/0/PB/0022/400/3/0/PB/0040/400/3/0/PB/0055/400/3/0/PC/0075/400/0011..B0 690PC/0110/400/0011..B0 690PC/0150/400/0011..B0 690PD/0180/400/0011..B0 690PD/0220/400/0011..B0 690PD/0300/400/0011..B0 690PE/0370/400/0011..B0 690PE/0450/400/0011..B0 690PF/0550/400/0011..B0 690PF/0750/400/0011..B0 690PF/0900/400/0011..B0 690PG/1100/400/0011..B0 690PG/1320/400/0011..B0 690PG/1600/400/0011..B0 690PG/1800/400/0011..B0 690PH/2000/400/0011..B0 690PH/2200/400/0011..B0 690PH/2500/400/0011..B0 690PH/2800/400/0011..B0
690PJ/3150/400/0011..B0 690+0175/400/CBN/UK
690PD/0220/400/PD/0300/400/PE/0370/400/PE/0450/400/PF/0550/400/PF/0750/400/PF/0900/400/PG/1100/400/PG/1320/400/PG/1600/400/PG/1800/400/PH/2000/400/PH/2200/400/PH/2500/400/PH/2800/400/PJ/3150/400/PB/0022/500/3/F/PB/0040/500/3/F/0011
690+0175/400/CNN/UK 690+0200/400/CBN/UK 690+0250/400/CBN/UK 690+0300/400/CBN/UK 690+0325/400/CBN/UK 690+0350/400/CBN/UK 690+0400/400/CBN/UK 690+0450/400/CBN/UK 690+0500/400/CBN/UK 690PD/0150/400/PD/0180/400/+0200/400/CNN/UK 690+0250/400/CNN/UK 690+0300/400/CNN/UK 690+0325/400/CNN/UK 690+0350/400/CNN/UK 690+0400/400/CNN/UK 690+0450/400/CNN/UK 690+0500/400/CNN/UK
*检测:我们将在收到货物后2-24小时内报价给您,经您同意后再维修;因其他原因不修,或无维修价值,我司尽快原机寄回给您;
报价参考:对*的产品维修价格为原新品的15%-35%不等(按故障的难易程度和所花时间来定)不知*格的产品则通过双方协商来定价;
*时间:标准维修时间为5-7个工作日,加急抢修为1-2个工作日(如遇到*元件不好采购则不按此标准执行);
保修时间:客户试机正常后算起对*的部位及相同的故障进行3个月的保修;
欧陆590 直流调速器维修案例一
故障现象:欧陆 590 直流调速器不能调速。
检查分析:经检查 +10v 电压基准电源为 2v 左右, -10v 电压基准电源为 -7v 左右,查看有一 ic 发热很大,更换后 -10v 电源正常,但 +10v 电源为 +13v ,再测量此 ic 附近有 2 个贴片电阻烧断,更换后± 10 电源正常,接上马达试机调速运行正常。
欧陆590 直流调速器维修案例二
故障现象: lcd 黑屏(但底板电源正常面板的正常指示灯及运行指示灯闪)
故障分析: 造成 lcd 黑屏的原因有两种:一是电源供给5v不正常;二是程序初始化未能正常执行。*初用示波器观测单片机 80c196kc晶振输入波形基本正常但有间歇性振荡幅度突降现象(间歇性周期约为 5ms )单片机 i/o 输出数据也为间歇性中断输出(*据状态且频率一致)因此故障电路指向 5v 电源及单片机的复位端信号正常与否?
结果表示: 复位端正常启动应为 h 电平而现为一脉冲,显然是这一脉冲导致i/o输出数据间歇性中断。 +5v 电源也有间歇性突降至 4v 现象,造成 +5v 电源突降4v 的可能,明显是电路中有元件受损跟随于这一间歇频率瞬时短路现象,从而造成单片和复位不成功,为此特意取消单片机电源复位保护信号 max825 芯片启动电源,短路故障( uln2003 发烫)出现,换上新的 uln2003 启通电正常。