■ Features | |||||
● Universal AC input/Full range | |||||
● Protections:Short circuit/Overload/Over voltage/Over temperature | |||||
● Built-in active PFC function | |||||
● UL1310 Cl* 2 power unit | |||||
● Cooling by free air convection | |||||
● Hiɡh reliability | |||||
● Suitable for LED daylight fluorescent lamp tube T8 and T10 | |||||
● Compliance to worldwide safety regulations for lighting | |||||
● Indoor application | |||||
● 2 years warranty | |||||
SPECIFICATION | |||||
MODEL | XZ-LC300030-B | XZ-LC360025-B | XZ-L*80018-B | XZ-LC600015-B | |
OUTPUT | DC Voltage Range | (20-30)V | (30-36)V | (36-48)V | (48-60)V |
Rated Current | 0.3A | 0.25A | 0.18A | 0.15A | |
Current Range | (0.28-0.30)A | (0.23-0.25)A | (0.16-0.18)A | (0.13-0.15)A | |
Output Power | 9W | 9W | 9W | 9W | |
Ripple&Noise Max Note.2 | |||||
Line regulation | &plu*n;3% | ||||
Load regulation | &plu*n;5% | ||||
Setup,Rising Time | 3S/230VAC ,4S/115VAC(at full load) | ||||
INPUT | Voltage Range | 90~264VAC 127-370VDC | |||
Frequency Range | 47-63Hz | ||||
Power Factor | PF≥0.95/100VAC ,PF≥0.90/230VAC at full load | ||||
Efficiency(T*.) | 81% | 81% | 81% | 81% | |
AC Current | |||||
Leakage Current | <0.75mA/240VAC | ||||
PROTE*ION | Over Current | 110% MAX | |||
Protection t*e:Constant current limiting,recover automatically after fault condition is removed | |||||
Short Circuit Note.3 | Hiccup mode: recovers automatically after fault condition is removed | ||||
Over Voltage | 1.1-1.2Vo | ||||
Protection t*e:Shut down output voltage,re-power on to recover | |||||
ENVIROMENT | Working Temp. | 20~+50°C(Refer to output load derating curve) | |||
Working Humidity | 20~90%RH,non-condensing | ||||
Storage Temp,Humidity | 40~+80°C,10~95%RH | ||||
Temp Coefficient | &plu*n;0.03%/°C(0~50°C) | ||||
Vibration | 10~500Hz,2G 10min/1cycle,period for 72min,each along X、Y、Z axes | ||||
SAFETY &EMC | Safety Standards | UL1310 Cl*2,TUV EN61347-1, EN61347-2-13,CAN/CSA C22.2 No.223-M91(expect for 48V) | |||
Withstand Voltage | I/P-O/P:3.0KVAC | ||||
Isolation Resistance | I/P-O/P:100M Ohms/500VDC/25°C/70%RH | ||||
EMI Conduction&Radiation | Compliance to EN55015,EN55022(CISPR22)Cl*B | ||||
Harmonic Current | Compliance to EN61000-3-2 Cl* C(≥75% load);EN61000-3-3 | ||||
EMS Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204,EN61547,light industry level(surge1KV),criteria A | ||||
*TE | 1.All parameters *T specially mentioned are measured at 230VAC input,rated load and 25ºC of ambient temperature. 2.Ripple&noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1uF&47uF parallel capacitor. Direct connecting to LEDs is not suggested for models with "RIPPLE&NIOSE">&plu*n;10% and using additional drivers is highly recommended. 3.Please refer to OLP characteristics 4.The power supply is considered as a component that will be operated in combination with final equipment.Since EMC performance will be affected by the complete installation,the final equipment manufactures must re-qualify EMC Directive on the complete installation again. |