图文详情
产品属性
相关推荐
1、描述/ D*CRIPTION:
本规格书适应于BX1203000型号的开关电源.
The purpose of the document is to specify the functional requirements of a60W switching power supply.
2、输入特性/INPUT CHARA*ERISTICS:
2.1输入电压/Input Voltage:
额定电压/Rated Voltage:100~240Vac
调整范围/Variation Range:90-264Vac
2.2输入频率/Input Frequency:
额定频率/ Rated Frequency: 50/60Hz.
调整频率/Variation Frequency:47-63Hz
2.3输入电流/Input Current:
当输入交流电压为额定值的下限电压负载满载时,*大输入交流电流1.5A.
1.5Amps max At any input voltage and rated, DC output rated load.
2.4浪涌电流/Inrush Current:
当输出为额定负载,环境温度为25℃,输入240Vac冷态起机时的*大浪涌电流小于50A.
50 Amps Max. Cold start at 240Vac input, with rated load and 25℃ambient.
2.5 AC漏电流/Ac Leakage Current:
当输入电压240Vac时,*大漏电流为0.25mA.
0.25mA Max.At240Vac input.
3、输出特性/OUTPUT CHARA*ERISTICS:
3.1输出功率/Power output
电压 Voltage | *小负载 Min. Load | 额定负载 Rated. Load | 峰值功率 Peak | 输出功率 Output power |
12Vdc | 0.00A | 3.0A | 70 | 60W |
3.2负载特性,调整率/Combined Load/Line Regulation
电压 Voltage | *小负载 Min. Load | 额定负载 Rated. Load | 线性调整 Line Regulation | 负载调整 Load Regulation |
12Vdc | 0.00A | 5.0A | &plu*n;1% | &plu*n;5% |
3.3纹波和噪音Ripple and Noise:
测试条件:在额定电压及额定负载条件下,使用示波器带宽为20MHz连接到充电器的输出端,同时输出端并联一个47uF的电解电容和一个0.1uF的瓷片电容.
Under nominal voltage and nominal load,the ripple and noise are as follows when measure with Max.Bandwidth of 20MHz and Parallel 47uF/0.1uF,crossed connected at testing point.
电压 *大纹波/*大噪音
Voltage Ripple and Noise(Max.)
12Vdc 120mV p-p
3.4启动延迟时间/Turn on delay time:
当输入115Vac和输出*大负载时,*大启动时间为3S.
3Second Max.at 115Vac input and output Max.load.
3.5上升时间/Rise time:
当输入115Vac和输出*大负载时*大时间为40 mS.
40 mS Max.at 115Vac input and output Max load.
3.6保持时间/Hold up time:
当输入115Vac和输出*大负载时,*小保持时间为5 mS .
5 mS Min.at 115Vac input and output Max.Load.
3.7效率/Efficiency:
当115/230Vac输入电压时,1/4,1/2,3/4和满载计算平均效率,*小83%。
83% Min, At 115/230Vac input voltage,1/4,1/2,3/4 and full load calculation average efficiency.
4、保护功能/PROTE*ION FUN*ION:
4.1短路测试/Short circuit test:
该电源供给器在短路解除时能正常工作恢复.
The power supply will be auto recovered when short circuit faults remove.
4.2过流保护/Over current Protection:
过流故障排除后,电源将自动恢复正常工作.
The power supply will be auto recovered when over current faults remove.
4.3过压保护/Over Voltage Protection:
当输出电压*过额定电压的120%~170%时,电源将保护,故障排除后能恢复正常工作.
The power supply will auto recovered when faults remove 120%~170%.
5、环境要求/ENVIRONMENTAL REQUIREMET:
5.1工作温度/Operating Temperature:
0℃-40℃,满载,正常工作.
0℃to 40℃,Full load, Normal operation.
5.2储藏温度/Storage Temperature:-20℃to 80℃
带外壳/With package
5.3工作湿度/Relative Humidity:
5%(0℃)~90%(40℃),72小时,满载,正常工作.
5%(0℃)~90%(40℃)RH,72Hrs,Full load,Normal operating.
5.4振动/Vibration:
1.测试标准:国际电工电子委员会
Operating: IEC 721-3-33M3
5~9Hz,A=1.5mm
加速度(9~200Hz,Acceleration5m/S2)
2.运输/Transportation:
IEC 721-3-22M2
5-9Hz,A=3.5mm
9~200Hz,加速度Acceleration=5m/S2
200~500Hz,加速度Acceleration=15m/S2
3.轴向振动/Axes,10 cycles per axis.
在测试过程中不能出现永久性的损坏.
No permanent damage may occur during testing.
在电源开启和关闭后,样机能够恢复到*初条件.
The SAMPLE has to restore to its original situation after power off/on..
5.5跌落试验/Dropping Packed:
插墙式跌落高度为1米、桌面式跌落高度为760mm;
1Mfor wallmount t*e and760mmfor desk* t*e as above described.
测试台面是厚13mm的夹木板,离地面高19-20mm
The horizontal surface consists of hardwood at least13mmthick, mounted on two layers of plywood
each19mmto20mmthick,all supported on a concrete or equivalent non-resilient floor.
6、*要求/SAFETY REQUIREMENT:
6.1*:*合标准UL/CUL-(UL60950-1),TUV/GS-(EN60950-1),CCC-(GB4943) , PSE- (J60950-1),EK-(K60950-1)
Safety: accord withUL/CUL-(UL60950-1),TUV/GS-(EN60950-1),CCC-(GB4943) ,PSE- (J60950-1),EK-(K60950-1)
6.2高压/DIELE*RIC STRENGTH Hi-Pot:
初级对次级/Primary to secondary:1800Vac10mA/3S for t*e test.
6.3 *缘*阻/ Iusulation resistance:
初级对次级/Primary to secondary:10MΩ min at 500V DC.
6.4 EMI标准/EMI STANDARD
Meets the Limits of/测试*合
<1>.Fcc part15 cl* B rules
<2>.EN55022 cl* B rules
<3>.GB9254-1998,GB17625.1-2003
7、结构参数/MECHANICAL REQUIREMENT:
7.1外壳/Enclosure:
外壳尺寸: L120x W53x H32mm;
The power supply size: L120x W53x H32mm;
7.2输入线/Input Connector:
IEC-320-C14.
12
100-240(V)
12(V)
&plu*n;20(%)
&plu*n;3(%)
36(W)
60mVp-p
LED电源
81(%)
BX-120500
推挽式
&plu*n;0.5(%)
FY
脉冲宽度调制(PWM)式
CE