5V1A电源适配器,5W开关电源,5V1A插墙式

地区:广东 深圳
认证:

深圳市益之源科技有限公司

普通会员

全部产品 进入商铺
品牌:EYA 型号:EAY-005100 适用产品:数码相框 输入电压范围:100-240VAC 输出电压:5VDC OEM:可OEM

INPUT:AC100-240V 50-60HZ

OUTPUT:DC5V1A

DC线长一米五,DC头5.5*2.1*10

1.SCOPE

The purpose of the document is to specify the functional requirements of a5Wswitching power supply.

2.INPUT CHARA*ERISTICS

2.1 Input Voltage:

Nominal Voltage:100-264Vac

2.2 Input Frequency: 47-63HZ

Nominal Frequency: 50HZ

Variation Frequency: 47-63HZ

2.3 Input Current:

0.1Arms max At any input voltage and rated, DC output rated load.

2.4 Inrush Current:

25Amps Max. Cold start at100Vacinput, with rated load and 25°Cambient.

2.5 Ac Leakage Current:

5mA Max At264Vacinput.

3.OUTPUT CHARA*ERISTICS

3. 1Power Output;

Voltage Min. Load Max. Load Peak Output Power

+5.0Vdc 0.1A 1A 1.2A 5W

3.2 Combined Load/Line Regulation:

Voltage Min. Voltage Max. Voltage Line Regulation Load Regulation

+5.0Vdc 4.75V 5.0V &plu*n;3% &plu*n;5%

3.3 Ripple and Noise:

The ripple and noise are as follows when measure with Max. Bandwidth of 20MHz and Parallel 47uF/0.1uF crossed connected at testing point.

Voltage Ripple And Noise(Max.)

+5.0Vdc 100mVp-p

3.4 Turn On Delay Time:

3 second Max. At100Vacinput and output Max. Load.

3.5 Rise Time:

40mS Max. At100Vacinput and output Max. Load.

3.6 Hold Up Time:

5mS Min. At100Vacinput and output Max. Load.

3.7 Efficiency:

70%Min.At100Vacinput and output Max. Load.

75%Min.At264Vacinput and output Max. Load.

3.8 Overshoot:

15%Max.When power supply at turn on or turn off.

4. PROTE*ION REQUIREMENT:

4.1 Short Circuit Protection:

The power supply will be auto recovered when short circuit faults remove.

4.2 Over current Protection

The power supply will be auto recovered when over current faults remove.

4.3 Over Voltage Protection

The power supply will not be auto recovered when faults remove.

5. ENVIRONMENTAL REQUIREMET:

5.1 Operating Temperature:

-20°Cto75°C,Full load Normal operation.

5.2 Storage Temperature: -20°Cto85°C, With package.

5.3 Relative Humidity:

5%(0°C)90%(40°C)RH,72Hrs,Full load Normal operating.

5.4 Vibration:

1.Operating: IEC 721-3-3 3M3

59Hz,A=1.5mm 9200Hz,Acceleration 5m/s2 2.TransportationIEC 721-3-2 2M2

5-9HzA=3.5mm

9200Hz, Acceleration=5m/S2

200500HZ, Acceleration=15m/S2

3. Axes. 10 cycles per axis.

No permanent damage may occur during testing.

The product has to restores its original situation after power off/on.)

5.5 Dropping Packed:

1 corner,3 edges, and 6 surfaces

76cm Height: 76cm

6. SAFETY AND EMC REQUIREMENT:

6.1 CE FCC UL EK

6.2 DIELE*RIC STRENGTH)(H-Pot

Primary to secondary:1500Vac/5mA/60s.

7. MECHANICAL REQUIREMENT

The power supply size:L73*W42*H27MM