供应GPS介质天线/GPS介质陶瓷片/内置天线

地区:广东 深圳
认证:

深圳市彩勤电子有限公司

普通会员

全部产品 进入商铺
品牌:彩勤 型号:DA1575S25 相对增益:1(dB) 频率范围:1575(MHz) 输出阻*:50(Ω) 工作电压:3.3(V) *大功率:1(W) 长度:2(mm)

此GPS天线介质陶瓷系列:尺寸有25*25 20*20 18*18 15*15 13 *13 12*12常用.60*60 30*30 多种尺寸规格可供客户选择要 .适用于卫星定位.导航系统.也可以客户指标订做

1. ELE*RICAL SPECIFICATIONS

*.

Part Number

Outline Dimension

Ground Plane

1-1

DA1575S25T2A

25*25*2mm

35*35mm

1-2

Center Frequency

1575&plu*n;3MHz

1-3

Bandwidth

15MHz min.

1-4

Impedance

50Ω

1-5

Gain @ Zenith

+3.5dBi t*ical

1-6

Frequency Temperature Coefficient

0&plu*n;10 ppm/

1-7

Return Loss @fo

20dB min.

2. STRU*URE AND MATERIAL

No.

Description

Structure and material

2-1

Antenna Substrate

Dielectric Ceramics

2-2

Pin

Copper, lead and tin plate

2-3

Electrode

Ag plated

2-4

Ground Base

Ag plated

3.PHYSICAL DIMENSIONS

4.ENVIRONMENTAL SPECIFICATIONS

Standard Condition : Temperature range:25&plu*n;3

Relative Humidity range: 55~75%RH

Operating Temperature range:-40~+85

Storage Temperature range: -40~+100

4.1 High TemperatureEndurance

The device should satisfy thespecification in Table 1after exposed to temperature 85&plu*n;5

for 24&plu*n;2 hours and 1~2 hours recovery time under normal temperature.

4.2 Low TemperatureEndurance

The device should also satisfy thespecification in Table 1after exposed to the temperature

-40℃&plu*n;5for 24&plu*n;2 hours and 1~2 hours recovery time under normal temperature.

4.3Moisture Proof

The device should satisfy thespecification in Table 1after exposed to the temperature 40&plu*n;2

and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under

normal condition.

4.4 Vibration Resist

The device should satisfy thespecification in Table 1after applied to the vibration of 10 to

55Hz with amplitude of 1.5mm for 2 hours each in X , Y and Z directions.

4.5Drop Shock

The device should satisfy the specification in Table 1 after dropping onto the hard wooden

board from the height of 30cm for 3 times each facet of the 3 dimensions of the device.

4.6 Temperature Cycle Test

The device should also satisfy thespecification in Table 1after exposed to the low

temperature -25and high temperature +85for 30&plu*n;2 min each by 5 cycles and 1 to 2

hours recovery time under normal temperature.