TBC-LTR系列电流传感器的初、次级之间是绝缘的,可用于测量直流、交流和脉冲电流.
电参数 |
|
TBC100LTP/LTR |
TBC200LTP/LTR |
TBC300LTPLTR |
|
额定输入有效值电流 |
100 |
200 |
300 |
A |
测量电流范围 |
300 ( ± 18V , 20 Ω) |
600 ( ± 18V , 30 Ω) |
900 (± 18V , 20 Ω) |
A |
匝 比 |
1:2000 |
1:2000 |
1:3000 |
|
测量电阻± 12V |
@ ± 100Amax 80(max) |
@ ± 200Amax 80(max) |
@ ± 300Amax 76(max) |
Ω |
|
@ ± 200Amax 25(max) |
@ ± 500Amax 27(max) |
@ ± 600Amax 22 (max) |
Ω |
with ± 15V |
@ ± 100Amax 110(max) |
@ ± 200Amax 120(max) |
@ ± 300Amax 100(max) |
Ω |
|
@ ± 200Amax 40(max) |
@ ± 500Amax 33(max) |
@ ± 600Amax 36(max) |
Ω |
额定输出有效值电流 |
50 ± 0.5% |
100 ± 0.5% |
100 ± 0.5% |
m A |
电源电压 |
|
|
± 12 ~± 18 |
V |
静态功耗电流 |
|
|
≤ 20 |
m A |
零电流失调 |
|
|
± 0.2 |
m A |
电流失调温漂 |
-40 ℃ ~ 85 ℃ |
|
± 0.5 |
m A |
响应时间 |
|
|
< 1 |
µ s |
线性度 |
|
|
≤ 0.1 |
% FS |
绝缘电压 |
50H Z ,1min |
|
6 |
KV |
di/dt跟随精度 |
|
|
> 200 |
A/u s |
带宽(-3dB) |
|
|
DC … 100 |
KHz |
次级线圈电阻 |
25 |
20 |
30 |
Ω |
工作温度 |
|
|
-40 ~ +85 |
℃ |
储存温度 |
|
|
-40 ~ +125 |
℃ |
结构参数 |
使用说明 |
1.在IP按箭头方向流动时,IS是正向;
2.初级导体温度不应超过100℃;
3.母排完全充满初级穿孔时动态表现(di/dt和响应时间)为最佳;
4.为了达到最佳的磁耦合,初级线匝应绕在传感器顶部。