极限条件/Absolute Maximum Ratings (unless otherwise specified)
参数/Parameters |
条件/Conditions |
规格/Specifications |
单位/Units |
|
|
|
最小/Min. |
最大/Max. |
|
工作温度/Operating Temperature |
产品正常工作时/Operating |
-5 |
65 |
oC |
工作湿度/Operating Humidity |
产品正常工作时/Operating |
5 |
95 |
%RH |
存储温度/Storage Temperature |
产品不工作时/Non_Operating |
-40 |
+85 |
oC |
存储湿度/Storage Humidity |
产品不工作时/Non_Operating |
5 |
95 |
%RH |
光性能/Optical Specification (高斯无热AWG/ Gaussian Athermal AWG)
参数/Parameters |
条件/Condition |
规格/Specs |
单位/Units |
||
Min |
Typ |
Max |
|||
通道数/Number of Channels |
|
16 |
|
||
通道间距/Number Channel Spacing |
200GHz |
200 |
GHz |
||
中心波长/Cha. Center Wavelength |
ITU频率/ITU frequency. |
C -band |
nm |
||
通带频率/Clear Channel Passband |
|
±25 |
GHz |
||
波长精度/Wavelength Stability |
Maximum range of the wavelength error of all channels and temperatures in average polarization. |
±0.05 |
nm |
||
-1 dB 带宽/-1 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.24 |
|
|
nm |
-3 dB 带宽/-3 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.43 |
|
|
nm |
插损/Optical Insertion Loss at ITU grid |
Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations. |
|
3.5 |
4.0 |
dB |
相邻通道隔离度/Adjacent Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the adjacent channels. |
25 |
|
|
dB |
非相邻通道隔离度/Non-Adjacent, Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of the nonadjacent channels. |
29 |
|
|
dB |
总隔离度/Total Channel Isolation |
Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels. |
22 |
|
|
dB |
插损一致性/Insertion Loss Uniformity |
Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures. |
|
|
1.5 |
dB |
方向性/ Directivity(Mux Only) |
Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n |
40 |
|
|
dB |
插损平坦度/Insertion Loss Ripple |
Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port |
|
|
1.2 |
dB |
回损/Optical Return loss |
Input & output ports |
40 |
|
|
dB |
PDL/Polarization Dependent Loss in Clear Channel Band |
Worst-case value measured in ITU band |
|
0.3 |
0.5 |
dB |
偏振模式色散/Polarization Mode Dispersion |
|
|
|
0.5 |
ps |
最大承受光功率/Maximum Optical Power |
|
|
|
23 |
dBm |
功率监控范围/MUX/DEMUX input/ output Monitoring range |
|
-35 |
|
+23 |
dBm |
1. IL Represents the worst case over a +/-0.01nm window around the ITU wavelength ;
2. PDL was measured on average polarization over a +/- 0.01nm window around the ITU wavelength.