Type T10FS
Accuracy class 0.1
Torque measuring system
Nominal (rated) torque Mnom N⋅m 500 1 k 2 k 3 k 5 k 10 k
for reference only ft–lb,500 2,250 3,750 7,500
Nominal sensitivity(range between torque = zero
and nominal (rated) torque)
Frequency output kHz 5
Voltage output V 10
Characteristic tolerance(deviation of the actual out-put quantity at Mnomfrom the nominal sensitivity)
Frequency output % "0.1
Voltage output % "0.2
Output signal at torque = zero
Frequency output kHz 10
Voltage output V 0
Nominal output signal
Frequency output
with positive nominal (rated) torque kHz 15 (5 V symmetric
1)
/12 V asymmetric
2)
)
with negative nominal (rated) torque kHz 5 (5 V symmetric
1)
/12 V asymmetric
2)
)
Voltage output
with positive nominal (rated) torque V +10
with negative nominal (rated) torque V –10
Load resistance
Frequency output kΩ ≥2
Voltage output kΩ ≥5
Long–term drift over 48 h
Voltage output mV ≤"3
Measurement frequency range
Voltage output Hz 0 ... 1000 (–3 dB)
Group delay time
Frequency output ms 0.15
Voltage output ms 0.9
Residual ripple
Voltage output mV 40 (peak-to-peak)
Temperature influence per 10 K in the nominal tem-perature range
on the output signal, related to the actual value of
signal span
Frequency output % <"0.1
Voltage output % <"0.2
on the zero signal, related to the nom. sensitivity
Frequency output % <"0.05 (<"0.03 optional)
Voltage output % <"0.15 (<"0.13 optional)
Power supply (version KF1)
Excitation voltage (square wave) V 54"5% (peak-to-peak)
Release of calibration signal V 80"5 %
Frequency kHz approx. 14
Max. current consumption A 1 (peak-to-peak)
Preamplifier excitation voltage V 0/0/+15
Preamplifier, max. current consumption mA 0/0/+25
Power supply (version SF1/SU2)
Nominal supply voltage (protective low voltage) V (DC) 18 ... 30; asymmetric
Current consumption in measuring mode A < 0.9
Current consumption in start-up mode A < 2
Nominal (rated) power consumption W < 12
Linearity deviation including hysteresis, related to
the nominal sensitivity
Frequency output % <"0.05 (<"0.03 optional)
Voltage output % <"0.07 (<"0.05 optional)
1.)
RS 422 complementary signals; factory settings version SF1/SU2 2.)
Factory settings version KF1 (no switching possible)
D