Model LT12x19
Features:
Long life construction
Plunger stop for quiet operation
DC solenoid applications only
UL recognized
Stainless steel guide tube
Teflon coated plunger
Electrical:
Coil Voltages: 6, 12, 24, 48, 110 VDC standard
Coil Termination: 6.5” Wire leads
22 AWG (standard)
Duty Cycle: 100% Continuous, 25% Intermittent,
10% Intermittent, 1% Pulse
Coil treatment: Tape Wrapped
Insulation Class: Class A Rating - 105°C (221°F)
Dielectric Strength: 1500V 60 Hz
Mechanical:
Size: 2.37” (L) x 1.5”(D)
Plunger Diameter: 0.5”
Plunger Guide Material: Stainless Steal
Mounting: Hex Nut
Weight: Plunger 2.2 oz, Total 14.6 oz
Life Expectancy: 10 Million Cycles1
1 - Dependent on load conditions
Model No. Part No. Duty Cycle Voltage Resistance2
(Ω)
Power
(W)
Current
LT12x19-C-12D A420-064866-00 Cont. 12VDC 14.8 10.2 811 mA
LT12x19-I-12D A420-064867-00 Inter. 12VDC 4.6 32.4 2.58 A
LT12x19-C-24D A420-064868-00 Cont. 24VDC 71.8 8.4 334 mA
LT12x19-I-24D A420-064869-00 Inter. 24VDC 18.6 32.5 1.29 A
2 - Coil resistance tolerance +/- 5%
Contact us for custom voltages or duty cycles
Optional Return
Spring Kit
A490-367460-18
Available Customization:
• Plunger
• Lead and Connector
• DC Voltage
• Duty Cycle
• Insulation systems up to class H 180° C (356° F)
* Minimum quantities apply
Typical Pull Force Ounces [N] @ 20°C (68°F)
(Distance from fully seated position)
HOLDING
FORCE
Ounces [N]
Power
(W)
Stroke (in.) 0.050 0.125 0.250 0.375 0.500 0.625 0.750 1.000
Continuous 100% 110 [30.6] 70 [19.5] 32 [8.9] 20 [5.6] 15 [4.2] 8 [2.2] 5 [1.4] 3 [0.8] 139 [38.6] 8.6
Intermittent 25% 170 [47.3] 140 [38.9] 97 [27] 75 [20.9] 45 [12.5] 35 [9.7] 20 [5.6] 10 [2.8] 160 [44.5] 32.4
Intermittent 10%3 233 [64.8] 212 [58.9] 166 [46.2] 137 [38.1] 110 [30.6] 87 [24.2] 78 [21.7] 45 [12.5] 455 [126.5] 83
Pulse 1%3 285 [79.2] 263 [73.1] 225 [62.6] 196 [54.5] 163 [45.3] 145 [40.3] 116 [32.2] 75 [20.9] N/A 130
Continuous Duty 100% = 100% On Time
Intermittent Duty 25% = 25% On Time (100 Seconds On Max Followed By 300 Seconds Off)
Intermittent Duty 10% = 90% On Time (10 Seconds On Max Followed By 90 Seconds Off)
Pulse Duty 1% = 99% On Time (1 Second On Max Followed By 99 Seconds Off)
3
- Calculated force values to be verified in application