Operating temperature range
|
Max. operating temperature Top, max +125 °C Upper category temperature Tmax +110 °C
Lower category temperature Tmin 55 °C
Rated temperature TR +85 °C
|
Dissipation factor tan δ
(in 10-3) at 20 °C
(upper limit values)
|
1 kHz
10 kHz
100 kHz
|
1.0
2.5
25.0
|
Insulation resistance Rins at 100 V and 20 °C, rel. humidity ≤ 65% ( minimum as-delivered values)
|
> 30 GΩ (CR ≤ 0.33 μF)
> 10000 s (CR > 0.33 μF)
|
DC test voltage
|
1.4 VR, 2 s
|
Category voltage VC
(continuous operation with
VDC or VAC at f ≤ 1 kHz) For 85 °C < TA the derating is 1.28% per °C
|
Top (°C)
|
DC voltage derating
|
AC voltage derating
|
Top ≤ 85
85 < Top ≤ 100 100 < Top ≤ 110
110 < Top ≤ 125
|
VC = VR
VC = 0.81 VR
VC = 0.68 VR
VC = 0.5 VR
|
VC,RMS = VRMS
VC,RMS = 0.81 VRMS
VC,RMS = 0.68 VRMS
VC,RMS = 0.5 VRMS
|
Operating voltage Vop for short operating periods (VDC or VAC at f ≤ 1 kHz)
|
TA (°C)
|
DC voltage (max. hours)
|
AC voltage (max. hours)
|
TA ≤ 100
110 < TA ≤ 125
|
Vop = 1.1 × VC (1000 h)
Vop = 1.0 × VC (1000 h)
|
Vop = 1.0 × VC,RMS (1000 h)
Vop = 1.0 × VC,RMS (1000 h)
|
Reliability:
|
|
Failure rate λ
Service life tSL
|
24 fit (≤ 1 10-7/h) at 0.5 VR, 40 °C
200000 h at 0.5 VR, 85 °C
For conversion to other operating conditions and temperatures, refer
|
Failure criteria:
|
to chapter "Quality, 2 Reliability"
|
Total failure
|
Short circuit or open circuit
|
Failure due to variation of parameters
|
Capacitance change ∆C/C > 10 %
Dissipation factor tan δ > 4 × upper limit values
Insulation resistance Rins < 150 MΩ (CR ≤ 0.33 μF)
Or time constant τ < 50 s (CR ≥ 0.33 μF)
|