This chapter covers the electrical and switching characteristics for MAX® V devices.
Electrical characteristics include operating conditions and power consumptions. This
chapter also describes the timing model and specifications.
You must consider the recommended DC and switching conditions described in this
chapter to maintain the highest possible performance and reliability of the MAX V
devices.
This chapter contains the following sections:
■ “Operating Conditions” on page 3–1
■ “Power Consumption” on page 3–10
■ “Timing Model and Specifications” on page 3–10
Operating Conditions
Table 3–1 through Table 3–15 on page 3–9 list information about absolute maximum
ratings, recommended operating conditions, DC electrical characteristics, and other
specifications for MAX V devices.
Absolute Maximum Ratings
Table 3–1 lists the absolute maximum ratings for the MAX V device famil