图文详情
产品属性
相关推荐
与groundflex®适配器型号6474和®groundflex传感器的主塔的接地电阻允许系统测量漏电流和接地电阻塔腿而不断开架空地线导体。
The Model 6472 measures from 0.01 to 99.99kΩ and is auto-ranging, automatically seeking out the optimum measurement range, test frequency and test current. Easy-to-use – Simply connect the leads, select test mode, press Start and read the results. Up to 512 test results can be stored in internal memory for recall to the display or downloaded to a PC via DataView® software.
The large LCD is easy-to-read and indicates ground electrode resistance, test voltage, current and frequency as well as individual electrode resistance, battery status and more. The Model 6472 is Cat IV rated to 50V and is over voltage protected to more than 250Vac against accidental live connection to live circuits. The voltage is also displayed on screen. In the event of a system fault, the Model 6472 can withstand 250Vac.Additional features of the Model 6472 include; manual and automatic test frequency selection from 40 to 5078Hz; user selectable 3 or 4-Pole Fall of Potential or 4-Pole Soil Resistivity test methods and user selectable 2-Wire or 4-Wire Bond Resistance test method.
The Model 6472 is powered by 9.6V, 3.5 Ah NiMH rechargeable batteries. An external recharger powered from 120/230V, 50/60Hz is included and provides for testing while recharging. The Model 6472 can also be vehicle powered from an optional 12V battery adapter.
Functional Displays
4-Point Bond Test
3-Point Fall-of-Potential Test
Frequency Current Schlumberger Test
The 4-Point Bond test displaying lead connections, bond resistance test results, test voltage and current.
The 3-Point Fall-of-Potential test displaying test lead connection, grounding electrode resistance, test voltage and frequency.
The Frequency selection screen displays selected test frequency and voltage for the test as well as lead connection.
Memory Recall
Schlumberger Test
Wenner Test
Memory Recall displays test results stored at a specific memory location.
The Schlumberger test displays test lead connection, soil resistivity (ρ) test results, test electrode resistance and more.
The Wenner test displays test lead connection, soil resistivity (ρ) test results, electrode spacing and resistance.
Specifications
Electrical
3-Point Measurement
Range (Auto-Ranging)
0.09Ω to 99.9kΩ
Resolution
0.01Ω to 100Ω
Test Voltage
Nominal 16 or 32VRMS user selectable
Resistance Measurement Frequency
41 to 5078Hz user selectable or automatic selection
Test Current
Up to 250mA
Accuracy
±2% of Reading + 1ct @ 128Hz
Soil Resistivity 4-Point Measurement
Test Method
Wenner or Schlumberger selectable with automatic calculation of test results in Ω-meters, Ω-cm or Ω-feet
Range(Auto-Ranging)
0.01 to 99.99kΩ; ρ Max: 999kΩm(display in kΩft is not possible)
Resolution
0.01 to 100Ω
Test Voltage
16 or 32V user selectable
Frequency
From 41 to 128Hz selectable
External Voltage Measurement
Range(Auto-Ranging)
0.1 to 65.0Vac/dc – DC to 440Hz
Accuracy
±2% of Reading + 1cts
Resistance Measurement(Bond Testing)
Measurement Type
2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) user selectable
Range(Auto-Ranging)
2-Pole 0.01Ω to 99.9kΩ; 4-Pole 0.001Ω to 99.99kΩ
Accuracy
±2% of Reading + 2cts
Test Voltage
16Vdc (+, - or auto polarity)
Test Current
Up to 250mA max
Data Storage
Memory Capacity
512 test results
Communication
Optically Isolated USB
Power Source
9.6V rechargeable battery pack
Recharging Source
110/220 50/60Hz external charger with 18Vdc, 1.9A output or 12V vehicle power
Included Accessories
6472 多功能数字接地电阻测试仪
AEMC
40-513hz
68870.0