供应CTSR0.3---1-P系列小电流传感器CTSR0.3-P/SP1

地区:陕西 西安
认证:

西安浩南电子科技有限公司

金牌会员12年

全部产品 进入商铺


CTSR0.3---1-P系列小电流传感器

 

Non-contact and accurate milliamps measurement single supplied (+5V)

 

Main characteristics:

· 2 standard models 

· PCB mounting 

· Small currents' measurement from 0.3 to 0.6 ARMS nominal 

· Accurate (1.9 % Max at +25°C with CTSR 0,3-P model and 1.5 % Max at +25°C with CTSR 0.6-P model) 

· Low offset drift 

· Compact unique design for all the models 

· Light: 28 g 

· Operating temperature range: -40 to +105°C 

· 5 years warranty 

 

Features:

· DC, AC, pulse, small currents' measurements with galvanic isolation 

· Single supply: 0,+5V 

· Non contact measurement with high aperture (Ø 20.1 mm) 

· Isolation test voltage: 5.4 KVRMS / 50 Hz / 1 min 

· Voltage output 

· Bandwidth DC to 9.5 KHz (- 1dB) 

· Closed-loop Fluxgate technology 

· High creepage and clearance distances (11 mm) for high insulation 

 

Standard compliance:

· EN 50178 for industrial applications such as: 

§ Solar panels inverters (earth leakage control) 

§ First human contact protection of PV arrays 

§ Medium power inverter (symmetry fault detection) 

§ Power sources (failure detection) 

§ UPS's 

§ SMPS's 

§ Current monitoring 

· UL 508 (UR marking) 

· European Directive EMC 2004 / 108 / EEC: CE marking 

· Using UL94-VO recognized materials 

· Low voltage directive 2006 / 95 / EEC 

· Safety IEC 61010-1 

· Suitable to fulfil VDE 0126-1-1 and UL 1741 

 

Remarks:

· Available with primary inserted conductor (CTSR xxx-TP model) 

· Designed for single or three phases residual current measurement (up to +/- 30A per wire, DC or AC) 

· Easy insertion of earth leakage wires thanks to the aperture (Ø 20.1 mm) 

· Bipolar currents measurements when single supplied 0/+5V 

· Self test function 

· Demagnetization function 

· These transducers can directly be connected to the 5V input of μ-controllers and instrumentation cards 

· CTSR models have an additional pin at the output for more flexibility in applications. This pin provides access to the internal voltage reference which can then be fed to the reference of an A/D converter (Analog Digital) This extra pin can also receive the internal reference (from 2.3 to 4 V) of the DSP (Digital Signal Processor) or A/D converters commonly used in Power Electronics, allowing cancellation of the reference temperature drift 

· Low current consumption 

· High overload capability 

· Possibilty to easily design up to 3 ARMS nominal version under request 

 

 

Product search results 

Model

Primary
Nominal
Value

Measuring
Range

Secondary
Signal

Supply
Voltage (V)

Accuracy (误差)

Mounting

 

 

CTSR0.3-P 

 

0.5 A 

1.2 V 

5-5 Uni 

1.9 

PCB 

 

 

 

CTSR 0.3-P/SP1 

 

850 mA 

0.743 V 

5-5 Uni 

1.5 

PCB 

 

 

 

CTSR 0.3-TP/SP4 

 

0.5 A 

1.2 V 

5-5 Uni 

1.9 

PCB 

 

 

 

CTSR 0.6-P 

 

0.85 A 

1.486 V 

5-5 Uni 

1.5 

PCB 

 

 

 

CTSR 0.6-TP/SP2 

 

0.85 A 

1.486 V 

5-5 Uni 

1.5 

PCB 

 

 

 

CTSR 1-P 

1 A 

1.7 A 

1.2 V 

5-5 Uni 

1.5 

PCB 

 

 

Technology : Fluxgate 

 

 

 


电流

0-1.7A

工作电压

5V

规格

CTSR0.3-P

误差

1.9&